Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
1.
Semin Thromb Hemost ; 50(1): 81-90, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36750217

RESUMO

Extracorporeal membrane oxygenation (ECMO) was first started for humans in early 1970s by Robert Bartlett. Since its inception, there have been numerous challenges with extracorporeal circulation, such as coagulation and platelet activation, followed by consumption of coagulation factors and platelets, and biocompatibility of tubing, pump, and oxygenator. Unfractionated heparin (heparin hereafter) has historically been the defacto anticoagulant until recently. Also, coagulation monitoring was mainly based on bedside activated clotting time and activated partial thromboplastin time. In the past 50 years, the technology of ECMO has advanced tremendously, and thus, the survival rate has improved significantly. The indication for ECMO has also expanded. Among these are clinical conditions such as postcardiopulmonary bypass, sepsis, ECMO cardiopulmonary resuscitation, and even severe coronavirus disease 2019 (COVID-19). Not surprisingly, the number of ECMO cases has increased according to the Extracorporeal Life Support Organization Registry and prolonged ECMO support has become more prevalent. It is not uncommon for patients with COVID-19 to be on ECMO support for more than 1 year until recovery or lung transplant. With that being said, complications of bleeding, thrombosis, clot formation in the circuit, and intravascular hemolysis still remain and continue to be major challenges. Here, several clinical ECMO experts, including the "Father of ECMO"-Dr. Robert Bartlett, describe the history and advances of ECMO.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Humanos , Heparina/uso terapêutico , Heparina/farmacologia , Coagulação Sanguínea , Anticoagulantes/uso terapêutico , Anticoagulantes/farmacologia , COVID-19/terapia
3.
J Cardiothorac Vasc Anesth ; 38(2): 388-393, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38129208

RESUMO

OBJECTIVES: To compare the incidences of postoperative thrombotic complications, transfusion of blood products, and chest tube output in congenital cardiac surgical patients who received either recombinant activated factor VII (rFVIIa) or 4-factor prothrombin complex concentrate (4F-PCC). DESIGN: We performed a retrospective study. SETTING: Patients who underwent surgery at a tertiary academic hospital. PARTICIPANTS: Pediatric patients who underwent cardiac surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Data were obtained from the Society of Thoracic Surgeons and the Pediatric Cardiac Critical Care Consortium databases, as well as from manual chart review. Adjusted p values were obtained from multivariate regression using age (days), surgeon (number), cardiopulmonary bypass time (minutes), and need for deep hypothermic circulatory arrest (yes/no). A total of 55 patients were included in the 4F-PCC group, and 89 in the rFVIIa group. The median dose of rFVIIa was 77 mcg/kg (46-88), and the median dose of 4F-PCC was 31 IU/kg (24-43). The incidences of thrombotic complications were 8% in the 4F-PCC group and 30% in the rFVIIa group (adjusted p = 0.023). No difference was reported between the groups regarding chest tube output on days 1 and 2 or transfusion of blood products. Using a sensitivity analysis with propensity matching, the incidence of thrombosis was 10% in the 4F-PCC group (n = 38), and 31% in the rFVIIa group (n = 39) (p = 0.036). No difference was reported in terms of bleeding or transfusion. CONCLUSIONS: This retrospective study suggested that the administration of rFVIIa was associated with a higher risk of thrombotic complications when compared to 4F-PCC, without benefits in terms of bleeding and transfusions.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Trombose , Humanos , Criança , Fator VIIa/efeitos adversos , Estudos Retrospectivos , Fatores de Coagulação Sanguínea/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Proteínas Recombinantes/efeitos adversos , Fator IX , Complicações Pós-Operatórias , Trombose/epidemiologia , Trombose/etiologia , Trombose/prevenção & controle
4.
Gan To Kagaku Ryoho ; 50(11): 1203-1205, 2023 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-38056875

RESUMO

The case is of a 66-year-old woman who visited a general practitioner with a chief complaint of cough. She was referred to the Internal Medicine Department of our hospital because an abnormal shadow was found in her chest X-ray examination. A CT scan suspected her to have a metastatic lung tumor, and gastric cancer was diagnosed on primary site search. The patient was started on G-SOX therapy. After 2 courses, she experienced massive hematemesis and was referred to the hospital. A CT scan revealed arterial bleeding into the stomach. She went into cardiac arrest shortly afterward, and cardiopulmonary resuscitation was started. Hemostasis was obtained by interventional radiology(IVR). Upper gastrointestinal endoscopy performed after hemostasis showed the tumor to be necrotic and shrunk. Bleeding from advanced gastric cancer is common; however, bleeding due to the effects of chemotherapy have been reported. We report a case of massive bleeding and cardiopulmonary arrest during chemotherapy.


Assuntos
Parada Cardíaca , Neoplasias Gástricas , Humanos , Feminino , Idoso , Neoplasias Gástricas/patologia , Hematemese/induzido quimicamente , Hemorragia , Parada Cardíaca/induzido quimicamente , Parada Cardíaca/terapia
5.
Artigo em Inglês | MEDLINE | ID: mdl-37913838

RESUMO

BACKGROUND: In pediatrics, implantable continuous-flow ventricular assist devices (IC-VAD) are often used as a "temporary" support, bridging children to cardiac transplantation during the same hospital admission. METHODS: We conducted a retrospective review of our consecutive patients undergoing IC-VAD support at a tertiary pediatric heart center between 2008 and 2022. RESULTS: We identified 100 IC-VAD implant encounters: HeartWare HVAD (67; 67%), HeartMate II (17; 17%), and HeartMate 3 (16; 16%). The median (range) age, weight, and body surface area at implantation were 14.1 (3.0-56.5) years, 54.8 (13.3-140) kg, and 1.6 (0.6-2.6) m2, respectively. Cardiomyopathy (58; 58%) was the most common etiology, followed by congenital heart disease (37; 37%, including 13 single ventricle). At 6 months of IC-VAD support, 94 (94%) encounters achieved positive outcomes: ongoing support (59; 59%), transplant (33; 33%), and cardiac recovery (2; 2%). Eighty-two encounters (82%) resulted in home discharge with ongoing VAD support, including 38 (46%, out of 82) requiring readmission and 7 (9%, out of 82) resulting in death. There was a clinically significant decrease in morbidity rates before versus after home discharge: bleeding (1.55 vs 0.06), infection (0.84 vs 0.37), and stroke (0.84 vs 0.15 event per patient-year). Overall, 86 encounters (86%) reached positive end points at the latest follow-up (64 transplant, 15 ongoing support, and 7 recovery). Infection (29%; 4 of 14) was the most common cause of negative outcomes, followed by cerebrovascular accident (21%; 3), and unresolved frailty (21%; 3). The estimated overall survival at 1, 2, and 5 years was 90%, 86%, and 77%, respectively. CONCLUSIONS: This study suggests the feasibility of outpatient management of pediatric IC-VAD support. The ability to offer true long-term support maximizes the potential of IC-VAD support, not limited to a temporary bridging tool for heart transplantation.

6.
Front Med (Lausanne) ; 10: 1237601, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37671395

RESUMO

For decades, unfractionated heparin (hereafter, heparin) has been the primary anticoagulant used for extracorporeal membrane oxygenation (ECMO) support. More recently, however, bivalirudin, a direct thrombin inhibitor, has emerged as an alternative. This systematic review based on PRISMA guidelines, aims to summarize 16 comparative studies and 8 meta-analysis and review articles published from January, 2011 till May, 2023 which directly compares ECMO courses using heparin versus bivalirudin as the anticoagulant. While this comparison is complicated by the lack of a standardized definition of major bleeding or thrombosis, our overall findings suggest there is no statistical difference between heparin and bivalirudin in incidence of bleeding and thrombosis. That said, some studies found a statistical significance favoring bivalirudin in reducing major bleeding, thrombosis, and the need for transfusions. We also offer essential guidance for appropriately selecting an anticoagulant and monitoring its effect in ECMO settings.

7.
10.
J Thromb Haemost ; 21(1): 164-174, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36695379

RESUMO

Activated protein C resistance (APC-R) due to the single-nucleotide polymorphism factor V Leiden (FVL) is the most common cause of hereditary thrombophilia. It is found predominantly in Caucasians and is uncommon or absent in other populations. Although FVL is responsible for >90% of cases of hereditary APC-R, a number of other F5 variants that also confer various degrees of APC-R and thrombotic risk have been described. Acquired APC-R due to increased levels of coagulation factors, reduced levels of inhibitors, or the presence of autoantibodies occurs in a variety of conditions and is an independent risk factor for thrombosis. It is common for thrombophilia screening protocols to restrict assessment for APC-R to demonstrating the presence or absence of FVL. The aim of this Scientific and Standardisation Committee communication is to detail the causes of FVL-independent APC-R to widen the diagnostic net, particularly in situations in which in vitro APC-R is encountered in the absence of FVL. Predilution clotting assays are not FVL specific and are used to detect clinically significant F5 variants conferring APC-R, whereas different forms of acquired APC-R are preferentially detected using the classical activated partial thromboplastin time-based APC-R assay without predilution and/or endogenous thrombin potential APC-R assays. Resource-specific recommendations are given to guide the detection of FVL-independent APC-R.


Assuntos
Resistência à Proteína C Ativada , Trombofilia , Trombose , Humanos , Resistência à Proteína C Ativada/diagnóstico , Resistência à Proteína C Ativada/genética , Fator V/genética , Fator V/metabolismo , Trombofilia/diagnóstico , Coagulação Sanguínea
11.
J Heart Lung Transplant ; 42(5): 637-644, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36610928

RESUMO

BACKGROUND: Ventricular assist device (VAD) support for failing Glenn circulation represents a unique challenge. METHODS: We conducted a retrospective review of clinical outcomes in patients with VAD support for failing Glenn circulation between 2010 and 2020 at a tertiary pediatric institution. RESULTS: Ten patients were included: INTERMACS profiles were 1 in 3 patients and 2 in 7 patients. The median age, weight, and body surface area were 3.2 years, 13.0 kg, and 0.5 m2, respectively. Seven patients (70%) were implanted with continuous-flow devices and 3 with para-corporeal devices. Nine patients (90%) received heart transplant, with a median support duration of 77 days. Four (67%) out of 6 patients supported with discharge-capable devices were managed as outpatients. Post-transplant survival was 100%, with a median (range) follow up duration of 3.5 (1.8-11.9) years. There were 3 neurologic complications in 3 patients (0.9 events per patient-year); 2 intraoperative events (fatal hypoxia and symptomatic embolic stroke) and 1 postoperative (asymptomatic subarachnoid hemorrhage). Pump thrombosis occurred in one patient (0.3 events per patient-year), requiring pump exchange at day 65. Five patients (50%) received concomitant Fontan completion (fenestrated in 1). The Fontan-upgraded patients (vs Glenn) tended to be larger (median (range): 15.9 (12.6-22.9) vs 9.1 (7.7-22.8) kg), older (4.7 (3.1-6.5) vs 1.1 (0.9-10.1) years) and had a higher PaO2/FiO2 ratio (192 (52-336) vs 76 (59-78) mm Hg) on postoperative day 1. CONCLUSION: Our experience suggests the feasibility of durable VAD support for failing Glenn circulation. Concomitant Fontan completion may be considered in select patients to improve oxygen delivery.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Criança , Humanos , Pré-Escolar , Coração Auxiliar/efeitos adversos , Pacientes Ambulatoriais , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia
13.
J Thorac Cardiovasc Surg ; 166(1): 201-211.e2, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36494210

RESUMO

BACKGROUND: There are scarce data describing outcomes of pediatric temporary ventricular assist device support. METHODS: A retrospective single-center study was conducted to review clinical outcomes of all consecutive patients with temporary ventricular assist device between 1996 and 2021. Given the complex clinical course in some patients requiring multiple temporary ventricular assist device runs, outcome analysis was based on "encounters" (hospitalizations with temporary ventricular assist device, regardless of the number of devices used). RESULTS: In total, 126 temporary ventricular assist devices were implanted in 108 patients, resulting in a total of 114 encounters: 70 (61%) extracorporeal centrifugal pumps and 44 (39%) catheter-based axial pumps. The median (range) age and weight at temporary ventricular assist device implant were 10.1 years (1 day to 42.8 years) and 33.6 (2.5-128) kg, respectively. Underlying etiologies of cardiac dysfunction were cardiomyopathy (34, 30%), cardiac transplant graft dysfunction (29, 25%), congenital heart disease (23, 20%; 9 single ventricle), myocarditis (22, 19%), and other (6, 5%). Interagency Registry for Mechanically Assisted Circulatory Support Profile was 1 in 75 (66%) and 2 in 39 (34%). Support configuration was left ventricular assist device (104, including 9 systemic ventricular assist devices), right ventricular assist device (5), and biventricular assist device (5). The median (range) support duration was 6 (1-61) days. Overall, 97 (85%) encounters reached a positive primary end point: bridge-to-recovery (55), bridge-to-bridge (31), and bridge-to-transplant directly with temporary ventricular assist device (11). Seventeen (15%) encounters resulted in death during temporary ventricular assist device support: multiorgan failure (12), stroke (4), and cardiac arrest (1). The 6-month survivals with catheter-based axial pumps and extracorporeal centrifugal pumps were 84% (95% confidence interval, 74-96) and 67% (95% confidence interval, 57-79), respectively (P = .08). The 1- and 5-year survivals of 82 hospital survivors were 90% and 84%, respectively. CONCLUSIONS: This study suggests temporary ventricular assist device support is feasible in children with favorable outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Criança , Humanos , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/terapia , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Tempo
14.
Pediatr Int ; 64(1): e15407, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36326636

RESUMO

BACKGROUND: Published data on coronavirus disease 2019 (COVID-19) convalescent plasma (CCP) use in children and obstetric patients are limited. We describe a single-center experience of hospitalized patients who received CCP for acute COVID-19. METHODS: A retrospective review of children 0-18-years-old and pregnant patients hospitalized with laboratory-confirmed acute COVID-19 who received CCP from March 1, 2020 to March 1, 2021 was performed. Clinical and laboratory data were collected to assess the safety of CCP administration. Antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) were measured in the CCP products and in patients before transfusion and at various time points post-transfusion. Correlation between the administered SARS-CoV-2 administered versus the SARS-CoV-2 anti-spike immunoglobulin response in patient serum was assessed. RESULTS: Twenty-two children and ten obstetric patients were eligible. Twelve pediatric and eight obstetric patients had moderate disease and ten pediatric and two obstetric patients had severe disease. Five pediatric patients died. Eighteen of 37 (48.6%) CCP titers that were measured met US Food and Drug Administration (FDA) criteria for high immunoglobulin G (IgG) antibody titer. There were no complications with transfusion. High-titer CCP showed a positive correlation with rise in patient total immunoglobulin levels only in obstetric patients but not in pediatric patients. Among pediatric patients, the median serum antibody level increased over time after transfusion. CONCLUSIONS: Coronavirus 2019 convalescent plasma was administered safely to our patients. Our study suggested that CCP did not interfere with endogenous antibody production. The antibody titer of CCP correlated with post-transfusion response only in obstetric patients. Randomized trials in pediatric and obstetric patients are needed to further understand how to dose CCP and evaluate efficacy.


Assuntos
COVID-19 , Humanos , Criança , Recém-Nascido , Lactente , Pré-Escolar , Adolescente , COVID-19/terapia , COVID-19/etiologia , SARS-CoV-2 , Imunização Passiva/efeitos adversos , Soroterapia para COVID-19 , Imunoglobulina G , Anticorpos Antivirais
15.
Crit Care Explor ; 4(10): e0776, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36311559

RESUMO

Bivalirudin, an IV direct thrombin inhibitor, and unfractionated heparin (UFH) are frequently used anticoagulants in the pediatric critical care setting. An accurate, specific, point-of-care test to quantify and detect anticoagulation resistance is not currently available. This study evaluates the ability of a rapid (< 10 min), micro-volume (< 50 uL) coagulation test to detect and quantify the anticoagulation effect of bivalirudin and UFH using a functional, clot time endpoint in pediatric critical care patients. DESIGN: Single-site retrospective laboratory sample analysis and chart review. SETTING: A 105-bed pediatric and cardiac ICUs delivering extracorporeal membrane oxygenation. SUBJECTS: Forty-one citrated, frozen, biobanked plasma specimens comprising 21 with bivalirudin and 20 with UFH from 15 anticoagulated pediatric patients were analyzed. Thirteen patients were on extracorporeal membrane oxygenation, one had a submassive pulmonary embolism, and one was on a left ventricular assist device. INTERVENTIONS: None. MEASUREMENT AND MAIN RESULTS: A Clotting Time Score (CTS) was derived on each sample. The CTS detected patients that had developed a pathologic clotting event with 100% sensitivity and 82% specificity compared with prothrombin time with 25% sensitivity/76% specificity and activated partial thromboplastin time with 0% sensitivity/0% specificity. Additionally, the CTS detected subtherapeutic anticoagulation in response to UFH in patients that were clinically determined to be UFH resistant requiring alternative anticoagulation with bivalirudin. CONCLUSIONS: The CTS appears to be a clinically valuable indicator of coagulation status in patients treated with either UFH or bivalirudin. Results outside of the therapeutic range due to inadequate dosing or anticoagulation resistance appeared to be associated with clot formation. CTS testing may reduce the risk of anticoagulation-related complications via the rapid identification of patients at high risk for pathologic thrombotic events.

16.
Vox Sang ; 117(12): 1391-1397, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36121192

RESUMO

BACKGROUND AND OBJECTIVES: Blood transfusion is frequently needed to maintain adequate haemostasis and improve oxygenation for patients treated with extracorporeal membrane oxygenation (ECMO). It is more so for neonates with immature coagulation systems who require surgical intervention such as congenital diaphragmatic hernia (CDH) repair. There is growing evidence suggesting an association between blood transfusions and increased mortality. The aim of this study is to evaluate the association of blood transfusions during the peri-operative period of CDH repair, among other clinical parameters, with mortality in neonates undergoing on-ECMO CDH repair. MATERIALS AND METHODS: We performed a single centre retrospective chart review of all neonates with CDH undergoing on-ECMO surgical repair from January 2010 to December 2020. Logistic regression was used to investigate associations with survival status. RESULTS: Sixty-two patients met the inclusion criteria. Platelet transfusions (odds ratio [OR] 1.42, 95% confidence interval [CI]: 1.06-1.90) in the post-operative period and ECMO duration (OR 1.17, 95% CI: 1.05-1.30) were associated with increased mortality. Major bleeding complications had the strongest association with mortality (OR 10.98, 95% CI: 3.27-36.91). Gestational age, birth weight, Apgar scores, sex, blood type, right versus left CDH, venovenous versus venoarterial ECMO and duration of ECMO before CDH repair and circuit change after adjusting for ECMO duration were not significantly associated with survival. CONCLUSION: Platelet transfusion in the post-operative period and major bleeding are associated with increased mortality in CDH neonates with surgical repair. The data suggest a need to develop robust plans for monitoring and preventing coagulation aberrancies during neonatal ECMO support.


Assuntos
Oxigenação por Membrana Extracorpórea , Hérnias Diafragmáticas Congênitas , Recém-Nascido , Humanos , Hérnias Diafragmáticas Congênitas/cirurgia , Estudos Retrospectivos , Razão de Chances , Transfusão de Sangue
17.
Pediatr Crit Care Med ; 23(10): e465-e475, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35687091

RESUMO

OBJECTIVES: Bivalirudin is a direct thrombin inhibitor that is being increasingly used for anticoagulation in children after ventricular assist device (VAD) implantation. While the data on bivalirudin use in pulsatile flow VADs are growing, reports on its use in patients on continuous flow (CF) VAD as well as comparisons of associated outcomes with unfractionated heparin (UFH) remain limited. DESIGN: Retrospective cohort study. SETTING: Single tertiary-quaternary referral center. PATIENTS: All patients less than 21 years old on CF-VAD support who received bivalirudin or UFH for anticoagulation between the years 2016 and 2020. INTERVENTIONS: Not applicable. MEASUREMENTS AND MAIN RESULTS: Clinical characteristics compared between the cohorts included time to target range of anticoagulation, markers of hemolysis, and prevalence of hemocompatibility-related adverse events such as major hemorrhagic complications, ischemic stroke, and pump thrombosis. In 42 unique patients (41 HeartWare HVAD [Medtronic, Minneapolis, MN], one HeartMate 3 LVAD [Abbott Laboratories, Abbott Park, IL]) during the study period, a total of 67 encounters of IV anticoagulation infusions (29 UFH and 38 bivalirudin) were retrospectively reviewed. In comparison with use of UFH, bivalirudin was associated with lesser odds of major bleeding complications (odds ratio [OR], 0.29; 95% CI, 0.09-0.97; p = 0.038). We failed to identify any difference in odds of major thrombotic complications (OR, 2.53; 95% CI, 0.47-13.59; p = 0.450). Eight of the patients (28%) on UFH were switched to bivalirudin due to hemorrhagic or thrombotic complications or inability to achieve therapeutic anticoagulation, while two of the patients (5%) on bivalirudin were switched to UFH due to hemorrhagic complications. Bivalirudin was used for a "washout" in eight cases with concern for pump thrombosis-six had resolution of the pump thrombosis, while two needed pump exchange. CONCLUSIONS: Use of bivalirudin for anticoagulation in patients on CF-VAD support was associated with lesser odds of hemorrhagic complications compared with use of UFH. Bivalirudin "washout" was successful in medical management of six of eight cases of possible pump thrombosis.


Assuntos
Coração Auxiliar , Trombose , Adulto , Anticoagulantes/efeitos adversos , Antitrombinas/efeitos adversos , Criança , Coração Auxiliar/efeitos adversos , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Heparina/efeitos adversos , Hirudinas/efeitos adversos , Humanos , Fragmentos de Peptídeos/efeitos adversos , Proteínas Recombinantes/efeitos adversos , Estudos Retrospectivos , Trombose/epidemiologia , Trombose/etiologia , Trombose/prevenção & controle , Resultado do Tratamento , Adulto Jovem
18.
J Thromb Haemost ; 20(7): 1735-1743, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35570324

RESUMO

Severe congenital protein C deficiency (SCPCD) is rare and there is currently substantial variation in the management of this condition. A joint project by three Scientific and Standardization Committees of the ISTH: Plasma Coagulation Inhibitors, Pediatric/Neonatal Thrombosis and Hemostasis, and Women's Health Issues in Thrombosis and Hemostasis, was developed to review the current evidence and help guide on diagnosis and management of SCPCD. We provide a summary of the clinical presentations, differential diagnoses, appropriate investigations to confirm the diagnosis, approaches for management of the acute situation, and options for long-term management including subsequent pregnancies. We finally provide a set of recommendations to help in this regard.


Assuntos
Coagulação Intravascular Disseminada , Deficiência de Proteína C , Trombose , Criança , Feminino , Hemostasia , Humanos , Recém-Nascido , Gravidez , Deficiência de Proteína C/diagnóstico , Trombose/diagnóstico , Trombose/terapia
19.
Int J Lab Hematol ; 44(3): 589-594, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34939341

RESUMO

INTRODUCTION: Unfractionated heparin is widely used as an anticoagulant for extracorporeal life support (ECLS) and usually monitored with activated partial thromboplastin time (aPTT). Due to its limitations in pediatric populations and interferences with monitoring, bivalirudin is being utilized more frequently in these settings. For bivalirudin, other tests have emerged such as dilute thrombin time (dTT) and ecarin chromogenic assay (ECA); however, their utilities in pediatrics are unexplored. Development of suitable, accurate testing for bivalirudin monitoring is paramount to prevent complications. We sought to compare aPTT, aPTT with heparinase (HPTT), dTT1:4, modified dTT1:10, and ECA for monitoring of pediatric ECLS patients anticoagulated with bivalirudin. METHODS: aPTT, HPTT, dTT1:4, dTT1:10, and ECA were measured in 51 specimens from 17 children on bivalirudin-anticoagulated ECLS. Normal pooled plasma was spiked with various bivalirudin concentrations, and aPTT, dTT1:4, dTT1:10, and ECA were measured. In addition, dTT assays were performed using plasma from normal donors spiked with bivalirudin, heparin, and cryoprecipitate. RESULTS: dTT1:4 showed excellent correlation with ECA, while dTT1:4 correlated moderately with aPTT or HPTT. Fifty to 75% of specimens showed discordant results between dTT1:4 and HPTT. We found that dTT1:4 and ECA prolongations are associated with bivalirudin infusion rate; however, there are age-based differences that should be accounted for. The performance of dTT1:10 was similar to dTT1:4, though it was less sensitive to interfering factors (heparin or hyperfibrinogenemia). CONCLUSION: dTT1:10 appears to be more suitable for routine practice due to fewer variations and lower cost for monitoring bivalirudin in pediatric ECLS.


Assuntos
Oxigenação por Membrana Extracorpórea , Anticoagulantes/farmacologia , Anticoagulantes/uso terapêutico , Criança , Heparina/uso terapêutico , Hirudinas , Humanos , Tempo de Tromboplastina Parcial , Fragmentos de Peptídeos , Proteínas Recombinantes/uso terapêutico
20.
Ann Thorac Surg ; 113(3): 1026-1035, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34826386

RESUMO

BACKGROUND: Research evaluating hemostatic agents for the treatment of clinically significant bleeding has been hampered by inconsistency and lack of standardized primary clinical trial outcomes. Clinical trials of hemostatic agents in both cardiac surgery and mechanical circulatory support, such as extracorporeal membrane oxygenation and ventricular assist devices, are examples of studies that lack implementation of universally accepted outcomes. METHODS: A subgroup of experts convened by the National Heart, Lung, and Blood Institute and the US Department of Defense developed consensus recommendations for primary outcomes in cardiac surgery and mechanical circulatory support. RESULTS: For cardiac surgery the primary efficacy endpoint of total allogeneic blood products (units vs mL/kg for pediatric patients) administered intraoperatively and postoperatively through day 5 or hospital discharge is recommended. For mechanical circulatory support outside the perioperative period the recommended primary outcome for extracorporeal membrane oxygenation is a 5-point ordinal score of thrombosis and bleeding severity adapted from the Common Terminology Criteria for Adverse Events version 5.0. The recommended primary endpoint for ventricular assist device is freedom from disabling stroke (Common Terminology Criteria for Adverse Events AE ≥ grade 3) through day 180. CONCLUSIONS: The proposed composite risk scores could impact the design of upcoming clinical trials and enable comparability of future investigations. Harmonizing and disseminating global consensus definitions and management guidelines can also reduce patient heterogeneity that would confound standardized primary outcomes in future research.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Hemostáticos , Criança , Oxigenação por Membrana Extracorpórea/efeitos adversos , Coração Auxiliar/efeitos adversos , Hemostasia , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...